authorJavier Carrasco <javier.carrasco.cruz@gmail.com>2024-01-30 22:06:48 +0100
committerGuenter Roeck <linux@roeck-us.net>2024-02-25 12:37:37 -0800
commit3af350929e752fe72f0457033d448bff9aac695a (patch)
tree3dffbb7c4d33a4982df300e2838186531a7d4841 /MAINTAINERS
parent8f89ac2b9bdec95e4a05612a198b4255dce2ca8a (diff)
downloadlinux-3af350929e752fe72f0457033d448bff9aac695a.tar.gz
hwmon: Add support for Amphenol ChipCap 2
The Amphenol ChipCap 2 is a capacitive polymer humidity and temperature sensor with an integrated EEPROM and minimum/maximum humidity alarms. All device variants offer an I2C interface and depending on the part number, two different output modes: - CC2D: digital output - CC2A: analog (PDM) output This driver adds support for the digital variant (CC2D part numbers), which includes the following part numbers: - non-sleep measurement mode (CC2D23, CC2D25, CC2D33, CC2D35) - sleep measurement mode (CC2D23S, CC2D25S, CC2D33S, CC2D35S) The Chipcap 2 EEPROM can be accessed to configure a series of parameters like the minimum/maximum humidity alarm threshold and hysteresis. The EEPROM is only accessible in the command window after a power-on reset. The default window lasts 10 ms if no Start_CM command is sent. After the command window is finished (either after the mentioned timeout of after a Start_NOM command is sent), the device enters the normal operation mode and makes a first measurement automatically. Unfortunately, the device does not provide any hardware or software reset and therefore the driver must trigger power cycles to enter the command mode. A dedicated, external regulator is required for that. This driver keeps the device off until a measurement or access to the EEPROM is required, making use of the first automatic measurement to avoid different code paths for sleep and non-sleep devices. The minimum and maximum humidity alarms are configured with two registers per alarm: one stores the alarm threshold and the other one keeps the value that turns off the alarm. The alarm signals are only updated when a measurement is carried out. Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com> Link: https://lore.kernel.org/r/20240130-topic-chipcap2-v6-5-260bea05cf9b@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'MAINTAINERS')
-rw-r--r--MAINTAINERS8
1 files changed, 8 insertions, 0 deletions
diff --git a/MAINTAINERS b/MAINTAINERS
index dd69696f3c0e83..b00657d2536f5d 100644
--- a/MAINTAINERS
+++ b/MAINTAINERS
@@ -1098,6 +1098,14 @@ F: Documentation/devicetree/bindings/perf/amlogic,g12-ddr-pmu.yaml
F: drivers/perf/amlogic/
F: include/soc/amlogic/
+AMPHENOL CHIPCAP 2 HUMIDITY-TEMPERATURE IIO DRIVER
+M: Javier Carrasco <javier.carrasco.cruz@gmail.com>
+L: linux-hwmon@vger.kernel.org
+S: Maintained
+F: Documentation/devicetree/bindings/hwmon/amphenol,chipcap2.yaml
+F: Documentation/hwmon/chipcap2.rst
+F: drivers/hwmon/chipcap2.c
+
AMPHION VPU CODEC V4L2 DRIVER
M: Ming Qian <ming.qian@nxp.com>
M: Zhou Peng <eagle.zhou@nxp.com>