ABI: sysfs-class-hwmon: document emergency/max/min temperature alarms
These attributes are widely used in the hwmon subsystem, but they still must be documented. Add tempY_emergency_alarm, tempY_max_alarm and tempY_min_alarm to the ABI documentation according to their current usage and access rights in the hwmon subsystem. Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com> Link: https://lore.kernel.org/r/20231116-hwmon_abi-v1-4-8bfb7f51145a@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/ABI/testing')
-rw-r--r--Documentation/ABI/testing/sysfs-class-hwmon27
1 files changed, 27 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-hwmon b/Documentation/ABI/testing/sysfs-class-hwmon
index 3d5e6142ef0cb..3dac923c9b0ef 100644
--- a/Documentation/ABI/testing/sysfs-class-hwmon
+++ b/Documentation/ABI/testing/sysfs-class-hwmon
@@ -381,6 +381,15 @@ Description:
RW
+What: /sys/class/hwmon/hwmonX/tempY_max_alarm
+Description:
+ Maximum temperature alarm flag.
+
+ - 0: OK
+ - 1: temperature has reached tempY_max
+
+ RO
+
What: /sys/class/hwmon/hwmonX/tempY_min
Description:
Temperature min value.
@@ -389,6 +398,15 @@ Description:
RW
+What: /sys/class/hwmon/hwmonX/tempY_min_alarm
+Description:
+ Minimum temperature alarm flag.
+
+ - 0: OK
+ - 1: temperature has reached tempY_min
+
+ RO
+
What: /sys/class/hwmon/hwmonX/tempY_max_hyst
Description:
Temperature hysteresis value for max limit.
@@ -457,6 +475,15 @@ Description:
RW
+What: /sys/class/hwmon/hwmonX/tempY_emergency_alarm
+Description:
+ Emergency high temperature alarm flag.
+
+ - 0: OK
+ - 1: temperature has reached tempY_emergency
+
+ RO
+
What: /sys/class/hwmon/hwmonX/tempY_emergency_hyst
Description:
Temperature hysteresis value for emergency limit.