Kernel driver e50sn12051¶
Supported chips:
Delta E50SN12051
Prefix: ‘e50sn12051’
Addresses scanned: -
Datasheet:
Provided by Delta upon request and NDA
Description¶
E50SN12051 is a 600W non-isolated 1/8th brick DC-DC power module.
This driver supports the E50SN12051 PMBus compliant monitor device.
The device provides measurements for:
Input voltage
Output current
Output voltage
Temperature
The driver is based on the PMBus core and exposes standard hwmon sysfs attributes.
Sysfs attributes¶
curr1_label |
“iout1” |
curr1_crit |
Critical maximum current. From IOUT_OC_FAULT_LIMIT register. |
curr1_crit_alarm |
Current critical high alarm. From IOUT_OC_FAULT status. |
curr1_input |
Measured current. From READ_IOUT register. |
curr1_max |
Maximum current. From IOUT_OC_WARN_LIMIT register. |
curr1_max_alarm |
Current high alarm. From IOUT_OC_WARN_LIMIT status. |
in1_label |
“vin” |
in1_alarm |
Input voltage alarm. |
in1_input |
Measured voltage. From READ_VIN register. |
in2_label |
“vout1” |
in2_crit |
Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register. |
in2_crit_alarm |
Voltage critical high alarm. From VOLTAGE_OV_FAULT status. |
in2_input |
Measured voltage. From READ_VOUT register. |
in2_max |
Maximum voltage. From VOUT_OV_WARN_LIMIT register. |
in2_max_alarm |
Voltage high alarm. From VOLTAGE_OV_WARNING status. |
temp1_crit |
Critical high temperature. From OT_FAULT_LIMIT register. |
temp1_crit_alarm |
Module temperature critical high alarm. Set by comparing READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT status is set. |
temp1_input |
Measured module’s hot spot temperature. From READ_TEMPERATURE_1 register. |
temp1_max |
Maximum temperature. From OT_WARN_LIMIT register. |
temp1_max_alarm |
Module temperature high alarm. Set by comparing READ_TEMPERATURE_1 with OT_WARN_LIMIT if TEMP_OT_WARNING status is set. |