Kernel driver e50sn12051

Supported chips:

  • Delta E50SN12051

    Prefix: ‘e50sn12051’

    Addresses scanned: -

    Datasheet:

    Provided by Delta upon request and NDA

Description

E50SN12051 is a 600W non-isolated 1/8th brick DC-DC power module.

This driver supports the E50SN12051 PMBus compliant monitor device.

The device provides measurements for:

  • Input voltage

  • Output current

  • Output voltage

  • Temperature

The driver is based on the PMBus core and exposes standard hwmon sysfs attributes.

Sysfs attributes

curr1_label

“iout1”

curr1_crit

Critical maximum current. From IOUT_OC_FAULT_LIMIT register.

curr1_crit_alarm

Current critical high alarm. From IOUT_OC_FAULT status.

curr1_input

Measured current. From READ_IOUT register.

curr1_max

Maximum current. From IOUT_OC_WARN_LIMIT register.

curr1_max_alarm

Current high alarm. From IOUT_OC_WARN_LIMIT status.

in1_label

“vin”

in1_alarm

Input voltage alarm.

in1_input

Measured voltage. From READ_VIN register.

in2_label

“vout1”

in2_crit

Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.

in2_crit_alarm

Voltage critical high alarm. From VOLTAGE_OV_FAULT status.

in2_input

Measured voltage. From READ_VOUT register.

in2_max

Maximum voltage. From VOUT_OV_WARN_LIMIT register.

in2_max_alarm

Voltage high alarm. From VOLTAGE_OV_WARNING status.

temp1_crit

Critical high temperature. From OT_FAULT_LIMIT register.

temp1_crit_alarm

Module temperature critical high alarm. Set by comparing READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT status is set.

temp1_input

Measured module’s hot spot temperature. From READ_TEMPERATURE_1 register.

temp1_max

Maximum temperature. From OT_WARN_LIMIT register.

temp1_max_alarm

Module temperature high alarm. Set by comparing READ_TEMPERATURE_1 with OT_WARN_LIMIT if TEMP_OT_WARNING status is set.