.. SPDX-License-Identifier: GPL-2.0-or-later Kernel driver lx1308 ==================== Supported chips: * Luxshare LX1308 Prefixes: 'lx1308' Addresses scanned: - Datasheet: Datasheet is not publicly available. Author: Brian Chiang Description ----------- The LX1308 is a high-efficiency, non-isolated, regulated 12V, 860W, digital DC/DC power module. The module operates from a 40V to 60V DC primary bus and provides a 12V regulated output voltage. It can deliver up to 860W continuous and 1300W in transient. The module has slow OCP and fast OCP. If the module output current is higher than slow OCP set point and the lasting time is also longer than the delay, the module will shut down and retry 3 time, if the fault still exists then module enter latch mode. If the module output current is higher than fast OCP set point then it shut down and enter latch mode. The driver is a client driver to the core PMBus driver. Please see Documentation/hwmon/pmbus.rst for details on PMBus client drivers. Usage Notes ----------- This driver does not auto-detect devices. You will have to instantiate the devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for details. Sysfs entries ------------- ======================= ====================================================== curr1_alarm Input current alarm curr1_input Input current (IIN) curr1_label "iin" curr2_crit Output over current fault threshold (slow OCP, 60ms delay) curr2_crit_alarm Output over current fault alarm curr2_input Output current (IOUT) curr2_label "iout1" curr2_max Output over current warning threshold (slow OCP, 60ms delay) curr2_max_alarm Output over current warning alarm in1_crit Input over voltage fault threshold in1_crit_alarm Input over voltage fault alarm in1_input Input voltage (VIN) in1_label "vin" in1_lcrit Input under voltage fault threshold in1_lcrit_alarm Input under voltage fault alarm in1_max Input over voltage warning threshold in1_max_alarm Input over voltage warning alarm in1_min Input under voltage warning threshold in1_min_alarm Input under voltage warning alarm in2_crit Output over voltage fault threshold in2_crit_alarm Output over voltage fault alarm in2_input Output voltage (VOUT) in2_label "vout1" in2_lcrit Output under voltage fault threshold in2_lcrit_alarm Output under voltage fault alarm in2_max Output over voltage warning threshold in2_max_alarm Output over voltage warning alarm in2_min Output under voltage warning threshold in2_min_alarm Output under voltage warning alarm power1_alarm Input power alarm power1_input Input power (PIN) power1_label "pin" power2_input Output power (POUT) power2_label "pout1" temp1_crit Over temperature fault threshold temp1_crit_alarm Over temperature fault alarm temp1_input Module hot spot temperature temp1_max Over temperature warning threshold temp1_max_alarm Over temperature warning alarm ======================= ======================================================